Sinumerik Alarm 4183 Channel %1 M auxiliary function number %2 used several times (%3 and %4)
Parameters:
%1 = Channel number
%2 = M auxiliary function number
%3 = MD identifier
%4 = MD identifier
Definitions:
In the specified machine data, a number has been used several times for the configuration of an M function.
Reactions:
– Alarm display.
– Interface signals are set.
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
Remedy:
Check the specified machine data and create a unique assignment of M auxiliary function numbers.
Program Continuation:
Switch control OFF – ON.
References
- Siemens Diagnostics Guide by Siemens