Sinumerik Alarm 4185 Channel %1 illegal auxiliary function configured %2 %3 %4


Sinumerik Alarm 4185 Channel %1 illegal auxiliary function configured %2 %3 %4

Parameters:
%1 = Channel number
%2 = Type of auxiliary function
%3 = Extension
%4 = Auxiliary function value

Definitions:
An auxiliary function has been illegally configured.
Predefined auxiliary functions cannot be reconfigured by user-defined auxiliary functions.

Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– Interface signals are set.
– Alarm display.
– NC Stop on alarm.

Remedy:
Reconfigure the auxiliary function.

Program Continuation:
Clear alarm with the RESET key.Restart part program