Sinumerik Alarm 4215 Channel %1 spindle %2 declaration as modulo axis missing
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
The spindle functionality requires a modulo axis (positions in [deg],.).
Reactions:
– Mode group not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– Alarm display.
– Interface signals are set.
Remedy:
Please inform the authorized personnel/service department.Set MD “ROT_IS_MODULO”.
Program Continuation:
Switch control OFF – ON.
References
- Siemens Diagnostics Guide by Siemens