Sinumerik Alarm 4320 Axis %1 function %2 %3 and %4 not allowed
Parameters:
%1 = String: Axis identifier
%2 = String: MD identifier
%3 = String: Bit
%4 = String: MD identifier
Definitions:
The functions declared by the specified machine data cannot simultaneously be active for one axis.
Reactions:
– Mode group not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– Alarm display.
– Interface signals are set.
Remedy:
Deactivate one of the functions.
Program Continuation:
Switch control OFF – ON.