Sinumerik Alarm 4336 Channel %1 orientable toolholder no. %2 for orientation transformation %3 does not exist
Parameters:
%1 = Channel number
%2 = Number of the orientable toolholder
%3 = Number of the orientation transformation that is to be parameterized with the orientable toolholder
Definitions:
The orientable toolholder, with whose data the orientation transformation is to be parameterized (see machine data $MC_TRAFO5_TCARR_NO_1/2), does not exist.
Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
– NC Stop on alarm at block end.
Remedy:
Enter a valid tool-carrier number.
Program Continuation:
Clear alarm with the RESET key.Restart part program
References
- Siemens Diagnostics Guide by Siemens