Sinumerik Alarm 4336 Channel %1 orientable toolholder no. %2 for orientation transformation %3 does not exist


Sinumerik Alarm 4336 Channel %1 orientable toolholder no. %2 for orientation transformation %3 does not exist

Parameters:
%1 = Channel number
%2 = Number of the orientable toolholder
%3 = Number of the orientation transformation that is to be parameterized with the orientable toolholder

Definitions:
The orientable toolholder, with whose data the orientation transformation is to be parameterized (see machine data $MC_TRAFO5_TCARR_NO_1/2), does not exist.

Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
– NC Stop on alarm at block end.

Remedy:
Enter a valid tool-carrier number.

Program Continuation:
Clear alarm with the RESET key.Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 4336 Channel %1 orientable toolholder no. %2 for orientation transformation %3 does not exist