Sinumerik Alarm 4350 Channel %1 axis identifier %2 machine data %3 not consistent with machine data %4


Sinumerik Alarm 4350 Channel %1 axis identifier %2 machine data %3 not consistent with machine data %4

Parameters:
%1 = Channel number
%2 = String: Axis identifier
%3 = String: MD identifier
%4 = String: MD identifier

Definitions:
MD 32410 JOG_AND_POS_JERK_ENABLE (jerk limitation) and MD 35240 ACCEL_TYPE_DRIVE (acceleration reduction) have been defined as the initial setting for an axis. However, the two functions cannot be activated at the same time for one axis.

Reactions:
– Alarm display.
– Interface signals are set.
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.

Remedy:
Please inform the authorized personnel/service department. Resetting of 32410 JOG_AND_POS_JERK_ENABLE or 35240 ACCEL_TYPE_DRIVE.

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 4350 Channel %1 axis identifier %2 machine data %3 not consistent with machine data %4