Sinumerik Alarm 6000 Memory reorganized using standard machine data


Sinumerik Alarm 6000 Memory reorganized using standard machine data

Definitions:
The memory management was not able to allocate the NC user memory with the values in the machine data. Because the total memory available is provided as dynamic and static memory for the NC user (e.g. for macro definitions, user variables, number of tool offsets, number of directories and files etc.) and therefore its size is not adequate.

Reactions:
– Alarm display.
– Interface signals are set.
– NC Start disable in this channel.
– NC not ready.
– Mode group not ready, also effective for single axes
– NC Stop on alarm.

Remedy:
Please inform the authorized personnel/service department.Redefine the NC memory structure!
A specific machine data for NC user memory allocation cannot be given as the cause of the alarm. Therefore, the MD initiating the alarm must be determined on the basis of the default values in the machine data by changing the user-specific memory structure step by step.
Usually, not just one machine data has been chosen too large and therefore it is advisable to reduce the memory area by a certain proportion in several MDs.

Program Continuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 6000 Memory reorganized using standard machine data