Sinumerik Alarm 61127 Channel %1 block %2 transmission ratio of tapping axis incorrectly defined (machine data)
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE84, CYCLE840.
Reactions:
– Alarm display.
– Interface signals are set.
– NC Start disable in this channel.
– Interpreter stop
Remedy:
Check machine data 31050 and 31060 in the appropriate gear stage of the drilling axis.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References
- Siemens Diagnostics Guide by Siemens