Sinumerik Alarm 61181 Channel %1 block %2 NCK software version unsufficient (missing TOOLCARRIER functionality)


Sinumerik Alarm 61181 Channel %1 block %2 NCK software version unsufficient (missing TOOLCARRIER functionality)

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
Swivelling is not possible with the current NCK software version. Alarm triggered by fol- lowing cycles: CYCLE800.

Reactions:
– Interpreter stop
– NC Start disable in this channel.
– Interface signals are set.
– Alarm display.

Remedy:
Upgrade NCK software.

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 61181 Channel %1 block %2 NCK software version unsufficient (missing TOOLCARRIER functionality)