Sinumerik Alarm 61241 Channel %1 block %2: No retraction plane defined for this machining direction.
Definitions:
–
Reactions:
– Interpreter stop
– NC Start disable in this channel.
– Interface signals are set.
– Alarm display.
Remedy:
Define more retraction planes.
Program Continuation:
Clear alarm with the RESET key. Restart part program