Sinumerik Alarm 61308 Channel %1 block %2 check measuring distance 2a


Sinumerik Alarm 61308 Channel %1 block %2 check measuring distance 2a

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
A traversing path for measuring was generated that’s size was specified by MD’s that describe the maximum distance before and after the switching position (workpiece edge) and that must have a value greater than 0.

Reactions:
– Interpreter stop
– NC Start disable in this channel.
– Interface signals are set.
– Alarm display.

Remedy:
• Enter a measuring distance that equals 0. Check MD 9752, 9753, 9754, 9755.

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 61308 Channel %1 block %2 check measuring distance 2a