Sinumerik Alarm 61332 Channel %1 block %2 change tool tip position
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The tool tip is below the measuring probe surface (e.g. for a ring gauge or cube).
Reactions:
– Interpreter stop
– NC Start disable in this channel.
– Interface signals are set.
– Alarm display. Remedy: Place the tool above the measuring probe surface.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References
- Siemens Diagnostics Guide by Siemens