Sinumerik Alarm 6422 Channel %1 tool move not possible. Magazine no. %2 not available.
Parameters:
%1 = Channel ID
%2 = Magazine number
Definitions:
The desired tool motion command – triggered from the MMC or PLC – is not possible. The magazine with the specified number is not available.
Reactions:
– Alarm display.
– Interface signals are set.
– NC Start disable in this channel.
Remedy:
• Check whether the magazine data have been defined correctly.
• If the PLC issued the command for motion: check whether the PLC program is correct.
• If the MMC issued the command for motion: check whether the MMC command was assigned correct parameters.
Program Continuation:
Clear alarm with the Delete key or NC START.
References
- Siemens Diagnostics Guide by Siemens