Sinumerik Alarm 6432 Function not executable. No tool assigned to tool holder/spindle
Parameters:
%1 = Channel ID
Definitions:
When an attempt is made to perform an operation that requires a tool to be located on the spindle. This can be the quantity monitoring function, for example.
Reactions:
– Alarm display.
– Interface signals are set.
Remedy:
Select another function, another toolholder/spindle, position tool on toolholder/spindle.
Program Continuation:
Clear alarm with the Delete key or NC START.
References
- Siemens Diagnostics Guide by Siemens