Sinumerik Alarm 6520 The value of the machine data %1%2 is too low
Parameters:
%1 = String: MD identifier
%2 = If required, field index
Definitions:
The machine data $MN_MM_PROTOC_NUM_FILES specifies the number of protocol files for the protocol users. However, more types are used than configured.
Reactions:
– Alarm display.
Remedy:
Increase machine data $MN_MM_PROTOC_NUM_FILES.
Program Continuation:
Clear alarm with the Delete key or NC START.
References
- Siemens Diagnostics Guide by Siemens