Sinumerik Alarm 75050 Channel %1 wrong MD configuration, error code %2


Sinumerik Alarm 75050 Channel %1 wrong MD configuration, error code %2

Parameters:
%1 = Channel number
%2 = Error code

Definitions:
Incorrect configuration in MD $MA_CC_MASTER_AXIS
%2 = 2 This or the CC_Master axis is a spindle.
%2 = 4 No coupling between rotary and linear axes.
%2 = 8 Axes must not be exchange axes.

Reactions:
– Alarm display.

Remedy:
Check machine data.

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 75050 Channel %1 wrong MD configuration, error code %2