Sinumerik Alarm 75062 Channel %1 axes not in standstill axis %2
Parameters:
%1 = Channel number
%2 = Axis name
Definitions:
The CC_Master and/or CC_Slave axes were not at standstill when the coupling was switched on.
Reactions:
– Alarm display.
Remedy:
Input G601 for path axes or enter a STOPRE before the CC_COPON command.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References
- Siemens Diagnostics Guide by Siemens