Sinumerik Alarm 75270 Channel %1 tool parameters incorrect
Parameters:
%1 = Channel number
Definitions:
The tool parameters are not the same as the settings for the handling transformation package (checked in interpolation).
Reactions:
– NC Stop on alarm.
– NC Start disable in this channel.
Remedy:
Correct tool parameters.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References