Sinumerik Alarm 75452 Axis %1 setpoint switchover not possible in the current state


Sinumerik Alarm 75452 Axis %1 setpoint switchover not possible in the current state

Parameters:
%1 = Axis name

Definitions:
The axes included in the setpoint exchange group are not all stationary (DB3x.DBB61.4) No ModeGroupReady signal One of the two axes in the setpoint exchange group is already configured in another active setpoint exchange. Enter a valid value in drive MD 63750: CTRLOUT_CHANGE_TAB[0.2] for the setpoint exchange to be activated equals zero. A new exchange has been requested via PLC before the function has been returned to its initial state.

Reactions:
– Alarm display.

Remedy:
Enter another axis number for the setpoint exchange in MD 63750.

Program Continuation:
Clear alarm with the RESET key. Restart part program