Sinumerik Alarm 8036 Option: it is not allowed to set different IPO cycles or position control cycles with NCU link.


Sinumerik Alarm 8036 Option: it is not allowed to set different IPO cycles or position control cycles with NCU link.

Definitions:
The option for activating the FAST_IPO_LINK has not been set. For NCU link, all Ipo or position control cycles must then be equal (see FAST-IPO-LINK description).

Reactions:
– Alarm display.
– Interface signals are set.
– NC not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.

Remedy:
• Buy option
• Do not activate different Ipo or position control cycles (see MN_IPO_SYSCLOCK_TIME_RATIO and MN_POSCTRL_SYSCLOCK_TIME_RATIO).

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 8036 Option: it is not allowed to set different IPO cycles or position control cycles with NCU link.