Sinumerik Alarm 8041 Axis %1: MD %2 reset, corresponding option not sufficient
Parameters:
%1 = Axis number
%2 = String: MD identifier
Definitions:
All of the axes selected in the machine data of the assigned option are used. Safety functions have been selected for too many axes in the axial machine data.The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).
Reactions:
– Alarm display.
Remedy:
– Interface signals are set.
– NC Start disable in this channel.
– NC Stop on alarm.
– Mode group not ready.
– Channel not ready.
– Channel not ready.
Program Continuation:
Switch control OFF – ON.
References
- Siemens Diagnostics Guide by Siemens