Sinumerik Alarm 8098 Invalid combination of options (%1)
Parameters:
%1 = Bit mask of options
%1 = Bit 0 (LSB) Nibbling
%1 = Bit 1 External language
%1 = Bit 2 Neural quadrant error compensation
%1 = Bit 3 Measurement level 2
Definitions:
The following restrictions apply to this module for the combination of options: The option “2-channel” and the options “external language”, “nibbling”, “neural quadrant error compensation” and “measurement level 2” are mutually exclusive!
Reactions:
– Alarm display.
– Interface signals are set.
– NC Start disable in this channel.
– NC Stop on alarm.
– Mode group not ready.
– Channel not ready.
Remedy:
Set the options accordingly.
Program Continuation:
Switch control OFF – ON.
References
- Siemens Diagnostics Guide by Siemens