Sinumerik Alarm 14840 Channel %1 block %2 incorrect value range for constant cutting speed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed cutting speed is not within the input range
Input range metric: 0.01 to 9 999.99 [m/min]
Input range inch: 0.1 to 99 999.99 [inch/min].
Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
Remedy:
Program cutting speed under address S within the permissible range of values.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
References
- Siemens Diagnostics Guide by Siemens