Sinumerik Alarm 15166 Channel %1 user system asup _N_ASUP_SPF not available
Parameters:
%1 = Channel number
Definitions:
By means of the machine data 11610 $MN_ASUP_EDITABLE the function “User-defined system asup” has been activated. However, the relevant user program could not be found in the specified search path:
• 1. /_N_CUS_DIR/_N_ASUP_SPF
• 2. /_N_CUS_DIR/_N_ASUP_SPF
The default system asups are used.
Reactions:
– Alarm display.
– Interface signals are set
Remedy:
Load the user-defined system asup in /_N_CUS_DIR/_N_ASUP_SPF or /_N_CMA_DIR/_N_ASUP_SPF laden.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References
- Siemens Diagnostics Guide by Siemens