Sinumerik Alarm 15340 Channel %1 block %2 invalid label as search target


Sinumerik Alarm 15340 Channel %1 block %2 invalid label as search target

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
Syntax error! A label must have at least 2 but no more than 32 characters, and the first two characters must be alphabetic or underscore characters. Labels must be concluded with a colon.

Reactions:
– Alarm display.

Remedy:
Repeat the input with corrected label.

Program Continuation:
Clear alarm with the Delete key or NC START.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 15340 Channel %1 block %2 invalid label as search target