Sinumerik Alarm 16120 Channel %1 block %2 invalid index for tool fine compensation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Mistake in programming: The 2nd parameter in the PUTFTOC command indicates for which tool parameter the value is to be corrected (1 – 3 tool lengths, 4 tool radius). The programmed value is beyond the permitted range. Permissible values are 1 – 4 if on-line tool radius compensation is allowed (see machine data ONLINE_CUTCOM_ENABLE), otherwise values 1 – 3.
Reactions:
– Alarm display. – Interface signals are set. – Correction block is reorganized.
Remedy:
Modify part program: Length 1 – 3 or 4 permissible for radius.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
References
- Siemens Diagnostics Guide by Siemens