Sinumerik Alarm 16200 Channel %1 block %2 spline and polynominal interpolation not available
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The spline and polynomial interpolation are options that are not contained in the basic version of the control.
Reactions:
– Alarm display.
-Interface signals are set.
– Correction block is reorganized.
Remedy:
Do not program spline and polynomial interpolation, or retrofit the necessary option.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
References
- Siemens Diagnostics Guide by Siemens