Sinumerik Alarm 16762 Channel %1 block %2 spindle %3 thread function is active


Sinumerik Alarm 16762 Channel %1 block %2 spindle %3 thread function is active

Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Spindle number

Definitions:
Mistake in programming: The spindle function cannot be executed at the present time. This alarm occurs when the spindle (master spindle) is linked with the axes by an interpolation function.

Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.

Remedy:
Modify part program. Deselect thread cutting or tapping.

Program Continuation:
Clear alarm with NC START or RESET key and continue the program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 16762 Channel %1 block %2 spindle %3 thread function is active