Sinumerik Alarm 16913 Mode group %1 channel %2 mode change: action %3 not allowed


Sinumerik Alarm 16913 Mode group %1 channel %2 mode change: action %3 not allowed

Parameters:
%1 = Channel number
%2 = Mode group number
%3 = Action number/action name

Definitions:
The change to the desired mode is not permitted. The change can only take place in the Reset state. Example: Program processing is halted in AUTO mode by NC Stop. Then there is a mode change to JOG mode (program status interrupted). From this operating mode it is only possible to change to AUTO mode and not to MDA mode!

Reactions:
– Alarm display.

Remedy:
Either activate the Reset key to reset program processing, or activate the mode in which the program was being processed previously.

Program Continuation:
Clear alarm with the Delete key or NC START.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 16913 Mode group %1 channel %2 mode change: action %3 not allowed