Sinumerik Alarm 17502 Channel %1 block %2 indexing axis %3 with Hirth tooth system stop is delayed


Sinumerik Alarm 17502 Channel %1 block %2 indexing axis %3 with Hirth tooth system stop is delayed

Parameters:
%1 = Channel number %2 = Block number, label %3 = Axis name

Definitions:
For the indexing axis, the ‘Hirth tooth system’ function is activated and the override has been set to 0 or another stop condition (e.g. VDI interface signal) is active. Since it is possible to stop only on indexing axes, the next possible indexing position is approached. The alarm is displayed until this position is reached or the stop condition is deactivated.

Reactions:
– Alarm display.

Remedy:
Wait until the next possible indexing position is reached or set override > 0 or deactivate another stop condition.

Program Continuation:
Alarm display showing cause of alarm disappears. No further operator action

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 17502 Channel %1 block %2 indexing axis %3 with Hirth tooth system stop is delayed