Sinumerik Alarm 17800 Channel %1 block %2 illegally coded position programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The position number n specified with the keyword FP=n is not permissible. Two absolute axis positions can be defined as fixed points via the axis-specific MD30 600 FIX_POINT_POS [n].
Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
Remedy:
Program keyword FP with machine fixed points 1 or 2. Example: Approach fixed point 2 with machine axes X1 and Z2. N100 G75 FP=2 X1=0 Z2=0
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
References
- Siemens Diagnostics Guide by Siemens