Sinumerik Alarm 18310 Channel %1 block %2 frame: illegal rotation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Rotations are not possible with NCU global frames.
Reactions:
– Alarm display.
– Interface signals are set.
– NC Stop on alarm.
– Interpreter stop
– NC Start disable in this channel
Remedy:
Modify part program.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References
- Siemens Diagnostics Guide by Siemens