Sinumerik Alarm 20121 Axis %1: Configuration error in compensation table %2
Parameters:
%1 = Axis name, spindle number
%2 = Compensation table
Definitions:
IInterpolatory compensation with tables. The settings for the specified table are not allowed. $AN_CEC_MAX >= $AN_CEC_MIN and $AN_CEC_STEP != 0 apply to system variables. This table is switched off automatically.
Reactions:
– Alarm display.
– Interface signals are set.
Remedy:
Please inform the authorized personnel/service department. Check and correct the characteristic data in the compensation table. If the error cannot be found, the alarm can be suppressed by switching off the table ($SN_CEC_TABLE_ENABLE) or switching off compensation in the axis ($MA_CEC_ENABLE).
Program Continuation:
Clear alarm with the RESET key. Restart part program
References
- Siemens Diagnostics Guide by Siemens