Sinumerik Alarm 20122 Compensation table %1: invalid axis assignment


Sinumerik Alarm 20122 Compensation table %1: invalid axis assignment

Parameters:
%1 = Compensation table

Definitions:
IInterpolatory compensation with tables. The input or output axes assignment in the given table is not allowed. $AN_CEC_INPUT_AXIS and $AN_CEC_OUTPUT_AXIS != 0 apply to system variables. This table is automatically switched off.

Reactions:
– Alarm display.
– Interface signals are set.

Remedy:
Please inform the authorized personnel/service department. Check and correct the axis assignment in the compensation table. If the error cannot be found, the alarm can be sup- pressed by switching off the table ($SN_CEC_TABLE_ENABLE) or switching off compensation in the axis ($MA_CEC_ENABLE).

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 20122 Compensation table %1: invalid axis assignment