Sinumerik Alarm 22013 Channel %1 block %2 dependent spindle %3 is in simulation.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Following spindle number
Definitions:
When coupling, no synchronism can be achieved if the following spindle/axis is in simulation mode and the lead spindle/axis is not.
Reactions:
– Alarm display.
Remedy:
Set the lead spindle/axis to simulation mode, or do not simulate the following spindle/axis ($MA_CTRLOUT_TYPE). If the differing settings have been selected on purpose, the alarm can be suppressed with the machine data 11410 SUPPRESS_ALARM_MASK Bit21 = 1.
Program Continuation:
Clear alarm with the Delete key or NC START.
References
- Siemens Diagnostics Guide by Siemens