Sinumerik Alarm 22320 Channel %1 block %2 PUTFTOCF command could not be transferred


Sinumerik Alarm 22320 Channel %1 block %2 PUTFTOCF command could not be transferred

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
The cyclic transfer of the PUTFTOCF data block (fine tool compensation) could not be performed because the transfer area is already occupied.

Reactions:
– Alarm display.
– Interface signals are set.
– Interpreter stop
– NC Start disable in this channel.
– NC Stop on alarm.

Remedy:
Check the part program, in particular with regard to the other channels. Is a data block being transferred by another channel?

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens