Sinumerik Alarm 26080 Channel %1 retraction position of axis %2 not programmed or invalid
Parameters:
%1 = Channel
%2 = Axis, spindle
Definitions:
No retraction position has been programmed for the axis trigger time or the position became invalid.
Reactions:
– Alarm display.
Remedy:
Preset value by means of POLFA(Axis,Type,Pos), with type = 1 (absolute) or type = 2 (incremental); type = 0 specifies the position as invalid.
Program Continuation:
Clear alarm with the Delete key or NC START.
References
- Siemens Diagnostics Guide by Siemens