Sinumerik Alarm 27030 Axis %1 function not supported on this 611D module


Sinumerik Alarm 27030 Axis %1 function not supported on this 611D module

Parameters:
%1 = Axis number

Definitions:
SINUMERIK Safety Integrated can be used only with the 611D Performance control modules with 2 measuring circuits per drive and cutoff relay. An attempt has been made to activate a safety function although no such module is plugged in.

Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.

Remedy:
Please inform the authorized personnel/service department. Replace module or switch off safety functions in MD $MA_SAFE_FUNCTION_ENABLE.

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens