Sinumerik Alarm 27225 PROFI safe: slave %1, configuration error %2


Sinumerik Alarm 27225 PROFIsafe: slave %1, configuration error %2

Parameters:
%1 = PROFIBUS slave address
%2 = Configuration error

Definitions:
An error occurred during the evaluation of the S7 PROFIBUS configuration for the specified slave. This is further specified in alarm parameter %2. %2 = PRM header: the PRM telegram for this slave could not clearly be interpreted.

Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.

Remedy:
Check and correct the S7 PROFIBUS configuration.

Program Continuation:
Switch control OFF – ON

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 27225 PROFI safe: slave %1, configuration error %2