Sinumerik Alarm 27240 PROFIsafe: DP M not running up, DP info: %1


Sinumerik Alarm 27240 PROFIsafe: DP M not running up, DP info: %1

Parameters:
%1 = Current information from the DP interface NCK-PLC

Definitions:
There is no DP configuration available to the NCK after the time specified via the MD $MN_PLC_RUNNINGUP_TIMEOUT.

Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– Interface signals are set.
– Alarm display.
– NC Stop on alarm.

Remedy:
• Increase MD $MN_PLC_RUNNINGUP_TIMEOUT
• Check the PLC operating status.
• Check the PLC operating system software version.
• Delete the F parameterization in the NCK MD.

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 27240 PROFIsafe: DP M not running up, DP info: %1