Sinumerik Alarm 27250 PROFIsafe: configuration in DP M changed; error code %1 – %2


Sinumerik Alarm 27250 PROFIsafe: configuration in DP M changed; error code %1 – %2

Parameters:
%1 = NCK project number
%2 = Current PLC project number

Definitions:
The DP master shows a modified S7 PROFIBUS configuration. Error-free operation can no longer be guaranteed. Communication with the F slaves is terminated. Stop D/E is triggered.

Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.

Remedy:
Restart the PLC/NCK.

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens