Sinumerik Alarm 61226 Channel %1 block %2 swivel head cannot be exchanged


Sinumerik Alarm 61226 Channel %1 block %2 swivel head cannot be exchanged

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
The parameter “Swivel data block” is set to “No”. In spite of this, an attempt has been made to change the swivel head.

Reactions:
– Interpreter stop
– NC Start disable in this channel.
– Interface signals are set.
– Alarm display.

Remedy:
Set the parameter “Swivel data block” in the start-up screen form “Rotary axes” to “Automatic” or “Manual”.

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 61226 Channel %1 block %2 swivel head cannot be exchanged