Sinumerik Alarm 61232 Channel %1 block %2 loading of magazine tool not possible


Sinumerik Alarm 61232 Channel %1 block %2 loading of magazine tool not possible

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
Only manual tools may be loaded into a swivel head in which the tools can only be manually loaded.

Reactions:
– Interpreter stop
– NC Start disable in this channel.
– Interface signals are set.
– Alarm display.

Remedy:
Load a manual tool into the swivel head or set the parameter “Tool change” in the start-up screen form “Rotary axes” to “Automatic”.

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 61232 Channel %1 block %2 loading of magazine tool not possible