Sinumerik Alarm 61234 Channel %1 block %2 ShopMill subroutine %4 cannot be executed, as it has not been tested by ShopMill


Sinumerik Alarm 61234 Channel %1 block %2 ShopMill subroutine %4 cannot be executed, as it has not been tested by ShopMill

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
Before a ShopMill subroutine can be used, it has to be tested by ShopMill. Alarm triggered by following cycles: E_HEAD.

Reactions:
– Interpreter stop
– NC Start disable in this channel.
– Interface signals are set.
– Alarm display.

Remedy:
The subroutine has to be simulated first in ShopMill or loaded into the ShopMill operating mode “Machine auto”.

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 61234 Channel %1 block %2 ShopMill subroutine %4 cannot be executed, as it has not been tested by ShopMill