Sinumerik Alarm 61338 Channel %1 block %2 positioning velocity is zero
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
For some measuring versions, e.g. measuring spigots, in addition to the actual measuring paths, intermediate paths were generated that are traversed with a specified feed.
Reactions:
– Interpreter stop
– NC Start disable in this channel.
– Interface signals are set.
– Alarm display.
Remedy:
Set the appropriate feed (plane feed/infeed) via MD 9757 or 9758.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References
- Siemens Diagnostics Guide by Siemens