Sinumerik Alarm 61800 Channel %1 block %2: External CNC system missing
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Machine data for external language MD18800: $MN_MM_EXTERN_LANGUAGE or option bit 19800 $ON_EXTERN_LANGUAGE is not set.
Reactions:
– Interpreter stop
– NC Start disable in this channel.
– Interface signals are set.
– Alarm display.
Remedy:
–
Program Continuation:
Internal
References
- Siemens Diagnostics Guide by Siemens