Sinumerik Alarm 120202 Waiting for a connection to the NC


Sinumerik Alarm 120202 Waiting for a connection to the NC

Definitions:
The operator panel is connected with the NC and PLC via a serial bus. This alarm occurs if the MMC is started for the first time and the NC/PLC ramp-up is not yet finished or the communication to these components is faulty. In connection with this alarm, all display values connected with the NC/PLC become invalid. Such faults are normal while the controls are ramping up (e.g. after resetting).

Reactions:
– Alarm display.

Remedy:
The alarm disappears automatically as soon as the fault situation has ended. If this alarm is continuously present, a wide variety of faults may be the cause. (e.g. wire breakage, NC/PLC not ramped up, faulty address/data transfer rate configuration of one of the bus nodes, etc.).

Program Continuation:
Internal

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 120202 Waiting for a connection to the NC