Sinumerik Alarm 300707 Axis %1 drive %2 basic cycle times of axes differ


Sinumerik Alarm 300707 Axis %1 drive %2 basic cycle times of axes differ

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
In a 2-axis module, the basic drive cycle for the two axes is not the same. This alarm can only occur with OEM users who have the 611D drive without the standard NCK interface. This makes it possible for axially different basic drive cycles to be transferred to the 611D modules.

Reactions:
– NC not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.

Remedy:
Please inform the authorized personnel/service department. Set the same basic drive cycle for both axes.

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 300707 Axis %1 drive %2 basic cycle times of axes differ