Sinumerik Alarm 300799 Axis %1 drive %2 data backup and reboot required
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
Since drive machine data have been changed, it is necessary to recalculate parameters. This is initiated by pressing the soft key CALCULATE. After calculating the control parameters, it is necessary to save the machine data and to reboot. The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).
Reactions:
– NC not ready.
– Channel not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.
Remedy:
The newly calculated data must be saved (Soft key: SAVE). The new parameters will become effective during the next boot procedure!
Program Continuation:
Switch control OFF – ON.
References
- Siemens Diagnostics Guide by Siemens