Sinumerik Alarm 310710 Axis %1 drive %2 distance-coded scale incorrectly parameterized


Sinumerik Alarm 310710 Axis %1 drive %2 distance-coded scale incorrectly parameterized

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
If a distance-coded scale is selected (MD 5011 bit 7=1) a length measuring system must also be configured (MD 5011 bit 4=1).

Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.

Remedy:
Check and, if necessary, correct MD 5011: ACTUAL_VALUE_CONFIG (actual value sensing configuration).

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 310710 Axis %1 drive %2 distance-coded scale incorrectly parameterized